ASTM A27 grade 415-205 floating roofs API 650 tanks

refrigerated tanks secondary components are those whose failure would not result in leakage of the liquid being stored. Secondary components also include those API 650 tanks components that are not in contact with the refrigerated liquid but are subject to the refrigerated temperature vapors and have a combined tensile and primary bending stress under design conditions that does not exceed 6000 lbf/in.2. Secondary components that could be designed within this reduced stress are roof plates, including roof manways and nozzles with their reinforcement, roof-supporting structural members, and shell stiffeners.

This specification, in conjunction with API 650 Standard, prescribes minimum standards for the API 650 tanks design, supply fabrication, erection, and testing of field erected welded steel storage tanks complete with accessories as specified herein and as shown on attached datasheets and/or drawings.

On March 17 th 2018, our Sudan customer purchased the SG295 cylinder steel coils through other country such as UAE,Turkey before they cooperate with us. After they research our regular customer in Uganda, UAE, and his friends in China, he is satisfied with our company. Our produced SG295 cylinder steel is mainly used to fabricate low temperature pressure vessels like gas cylinder. The customer is very satisfied to our API 650 tanks quality control and professional arrangement for the SG295 steel order.

}

The construction period comparison of mechanical cleaning and manual cleaning for vertical storage tank, API 650 tanks. The API 650 tanks mechanical cleaning period is short, and the construction period is not affected by the size of the storage tank and the amount of sludge in the tank, and the cleaning equipment operates 24 hours a day. The manual cleaning of the API 650 tanks has a long construction period, which is easily affected by the external environment, and the number of workers is limited by the size of the storage tank and the amount of sludge.

We should focus on the main problems to be solved and pay attention to efficiency. After receiving the user's quality objection report data, the possible causes, responsible units, compensation amount, etc. of the problem shall be judged based on experience. To have a clear service plan, to be clear about what your main problem is, what technical support is needed, these should be prepared.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!