API 650 cylindrical welded storage tanks Liquid Relief ValvesA tank, which is likely to operate completely filled with liquid, shall be equipped with one or more liquid relief valves at the top of the roof, unless otherwise protected against overpressure. When such valves are, in effect, supplementary relief devices, they may be set at a pressure not greater than 1.25 times the design pressure. Because the relief valve at the pump, which provides the inflow of liquid to the tank, is set at a pressure greater than 1.25 times the design pressure of any tank that may be built under these rules, provision should be made for preventing overfilling of the tank by a self-closing float valve, by some practicable pilot-valve control, or by any other proven device.
Under the action of the earthquake, API 650 storage tank is mainly damaged by the phenomenon of the lower part of the API 650 cylindrical welded storage tanks tank wall. Therefore, the key point of seismic calculation is to prevent the tank wall from buckling under axial pressure.
The API 650 cylindrical welded storage tanks must go through strict inspection before putting into use. Inspection of plate groove of API 650 cylindrical welded storage tanks, vertical oil tank: After finishing the groove processing of oil tank plate, it is necessary to conduct dye penetrant inspection on the groove. This process is mainly aimed at the hard damage of groove in the machining process and the defects of the plate itself. If any defect is found, it shall be processed again until the defect disappears.