API Std 650 welded storage tanks top-angle attachment for self-supporting roofs
Bearing on FoundationsFoundations shall preferably be designed to resist the load exerted by the API Standard 620 tank and its contents when the tank is filled with water to the design liquid level. Foundations shall be designed at least for the maximum operating conditions including the wind load. During the API Std 650 welded storage tanks water test, the total load on the foundation shall not exceed 125% of the allowable loading. If necessary, the water level during the test may be reduced below the design liquid level line so as not to exceed the 25% maximum overload (see Q.8.1.2).
API 650 storage tank stipulates that if the thickness of the lower wall panel obtained by calculating the anti-overturning moment is greater than the thickness of the API Std 650 welded storage tanks hydrostatic pressure test (both do not include the corrosion allowance).
The lip seal of floating roof storage tank, API Std 650 welded storage tanks relies on the sliding contact between elastic lip and tank wall. This kind of seal has strong applicability, but the requirements of manufacturing technology and material selection are high, and the determination of elastic seal also exists. The secondary seal of floating roof storage tank, API Std 650 welded storage tanks is to add a seal on the basis of primary seal. It is proved by experiments that the secondary seal can reduce the liquid consumption by more than 50%, and has a more significant effect in safety.