API Std 650 SUG III tanks dynamic liquid hoop forces
In the petrochemical industry and other industries, large vertical API Std 650 SUG III tanks are often used to store various production raw materials. Usually, the medium with high melting point and easy to crystallize at room temperature can be exported and used after heating, which involves the heating of large vertical storage tanks. The heating system is an auxiliary facility for heating of large vertical storage tank. It is often necessary to design external heating coil or internal heating coil system.
All welded seams in the API Std 650 SUG III tanks bottom, and complete penetration and complete fusion sidewall-to-bottom welds, shall be inspected by means of a vacuum box test as described in Q.8.2.1. Sidewall-to-bottom welds not having complete penetration and complete fusion shall be inspected by means of either a vacuum box test of the inside weld as described in API 620 specification Q.8.2.1, or where approved by the Purchaser, a direct pressure solution film test as described in Q.8.2.2.
The outer layer of API 650 tank is glass fiber reinforced plastic layer with a thickness of more than 2.5mm, which API Std 650 SUG III tanks has strong corrosion resistance and electric corrosion resistance. Special process technology is used between the two layers to make the gap reach 0.1 mm, so as to eliminate the existence of potential safety hazard from the root.