API Std 650 storage tanks lap-welded bottom joints
For floating roof API 650 tanks, the net working capacity is the liquid volume contained between the API Std 650 storage tanks maximum operating level (300 mm below rim for metallic type seals and 600 mm below rim for fabric type seals) and the minimum operating level (API 650 tanks roof supports clearing the tank bottom by 25 mm while set at the operating position).
The density of the liquid API 620 large welded, low pressure storage tanks stored shall be its maximum density within the range of design temperatures, but no less than 36 lbf/ft3. The maximum allowable tensile stress shall be taken from Table 5-1 or Table Q-3. For the maximum allowable stresses for design loading combined with wind or earthquake loads, see API Standard 620 5.5.6 for carbon steel and Q.3.3.5 for stainless steel and aluminum.
After using for a certain period of time, it is necessary to check the corrosion protection of the metal oil tank and paint the outer wall of the API Std 650 storage tanks with anti-corrosion paint. The inlet and outlet valves of API Std 650 storage tanks shall be inspected and maintained regularly to ensure they are in good condition. Oil tank will produce a lot of dirt when it is stored for a long time. Usually, the cleaning cycle of metal oil tank is about three to five years.
We have a stable system and professional human resource management work as the support, from the six aspects of guidance, cohesion, incentive, constraint, radiation and stability, we continue to introduce, modify and train employees from concept to action, and shape employees through constant guidance of common values.
The company uses outsourced logistics operations. Our cooperated professional third-party logistics providers use the advantages of large-scale production and cost advantages to achieve cost savings by increasing the utilization of resources in each link, so that we can benefit from the separation of cost structure. Therefore, we can also provide customers with better, faster and more efficient cargo transportation, delivery, and lower freight costs.
When providing technical services on site, the after-sales personnel shall strictly abide by the safety rules and regulations of the construction site, consciously take safety protection measures (such as wearing safety helmet when entering the construction site), accept the supervision and management of the site; without permission on the construction site, they shall not dismantle, smear or damage any goods; the commissioning of contract goods shall be carried out under the supervision of the site supervisor If necessary, it shall be approved by the site supervisor or the person in charge of the project department.