API Std 650 self anchored flatbottom tanks convective (sloshing) period

Before the start of erection, inspect each API 650 tank foundation to ensure that it is level and acceptable to receive Work. Remove temporary erection attachments welded to the interior or exterior of the API Std 650 self anchored flatbottom tanks shell or to the bottom by arc gouging, and grind weld area smooth.

Static storage loss is also known as "small breathing" consumption. The rise and fall of the temperature in the API Std 650 self anchored flatbottom tanks leads to the increase and decrease of the pressure in the tank, which makes the mixed oil gas discharged from the tank, and the external air is sucked into the tank, resulting in the oil consumption. Fluid level loss is also called "big breathing" loss. It is the oil consumption caused by the change of gas space volume in the API Std 650 self anchored flatbottom tanks during the oil receiving and sending operation, which causes the mixed oil gas to be discharged out of the tank, and the external air is sucked into the tank, resulting in the oil consumption due to the change of liquid level height.

Large Low-Pressure Tanks Corrosion Allowance
In cases in which the rate of corrosion is closely predictable, additional metal thickness over and above that required for the initial operating conditions shall be provided and shall be at least equal to the expected corrosion loss during the desired life of the tank.
When corrosion effects are indeterminate before the tank is designed (although they are known to be inherent to some degree in the service for which the tank is to be used), and when corrosion is incidental, localized, or variable in rate and extent, the best judgement of the API Std 650 self anchored flatbottom tanks designer must be exercised in establishing reasonable maximum excess tank wall thicknesses. For all tanks that come under this classification, a minimum corrosion allowance of 1/16 in. shall be provided.

The impression of most customers who have cooperated with us on the company is being professional and responsible. That mainly owe to our united and considerate team members. For example, the professional technician, the responsible QC inspector, the experienced sales person, the rigorous document maker, the patient after-sales, etc. Their selfless devotion bring the customer good experience, and bring the company good reputation.

As a leading international steel supplier, we have two warehouses, close to Tianjin port and Shanghai port. This superior geographical location effectively saves the domestic transportation cost and greatly improves our service level. At the same time, it also shortens our delivery time and provides more convenience for customers.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!