API Std 650 cylindrical tanks tank-bottom reinforcing plate

In this project, an area of steel storage oil tank wall is constructed of ASTM A285, Grade C, steel plate that is 5/8-in. thick and has spot-radiographed, double-welded butt joints. The wall is subject to tension in a meridional direction and to compression in a latitudinal direction. The values of R1 and R2 at the point under consideration are 75 in. and 300 in. respectively. A corrosion allowance of 1/16 in. is required. The computed (meridional) tensile stress, stc, in the net thickness after deduction of the corrosion allowance is 6000 lbf/in.2.

Before pressure test, the main drain hose system of API 650 petroleum storage tank floating roof should be thoroughly flushed. Provide blind flanges, gaskets and bolts required for the API Std 650 cylindrical tanks test (other types of covers are also required if necessary). Covers for maintenance shall be provided in accordance with the interfaces specified by API 650 petroleum storage tanks, and these seals shall remain in place after the test; and for those interfaces that are not provided for maintenance covers, the covers can be removed after the API Std 650 cylindrical tanks test.

BBN had provided API Std 650 cylindrical tanks Hardox plates for more than 15 years for widely applied in coal mining machinery, cement equipment, road construction machinery, engineering machinery, dump trucks, metallurgical area and port fields. In 2016,we brought our customer to visit our API Std 650 cylindrical tanks NM400 steel plate producing line and our Shanghai warehouse for 30000 tons plate and structure. As a result, Our client purchased 500 tons NM 400 as first order, which is shipped by 3 times. In future, BBN will always guarantee that all the delivery condition for Hardox plate provided will be with quenching and tempering, which is the best delivery type according GBT 24186 standard.

}

Due to the volatility of oil products, the volatile consumption of oil products is inevitable in the storage process of large oil storage tanks such as API Std 650 cylindrical tanks. The volatilization of oil causes economic losses and pollution to the environment. Especially in the open air environment, large-scale oil storage tanks in the petrochemical industry will continue to accumulate energy when exposed to the sun, causing their surface and interior to heat up rapidly, causing sun overheating, and accelerating the volatilization of oil. How to effectively reduce the volatile consumption of large oil storage tanks?

Through the operation and management, brand advantage and improve pre-sales, sale of after-sales service, the efforts of the company into the industry leading enterprises.Relying on perfect quality management system, it has built up competition predominance and provided high quality, favorable price and perfect after service for customers.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!