API Std 650 cylindrical liquid-storage tank roof manufacturer
The company focuses on teamwork and builds a team with a dream. For society: we focus on quality first, integrity-based, service-oriented create value for customers and wealth for the society. For employees, the company promote healthy living, happy work, unity, innovation. For working, we seek the efficient operation, the pursuit of excellence. Welcome to come, visit our office building and join us.Impact Test Requirements for Oil storage tanks Primary ComponentsAll API Std 650 cylindrical liquid-storage tank primary components of 9% or 5% nickel steel shall be impact tested in accordance with Q.2.2.2 through Q.2.2.4. Impact testing is not required for primary components of austenitic stainless steel, nickel alloy, and aluminum materials. Welds in high-alloy (austenitic) stainless steel shall be impact tested if required by Q.6.3.Impact testing of plates, including structural members made of plate, shall comply with the following:a)Impact test specimens shall be taken transverse to the direction of final plate rolling. b)Charpy V-notch specimens shall be cooled to a temperature of –320°F for A353, A553, and A645 steels for impact testing.Standard API 650 tank calls for calculations based on the specific gravity of the liquid product being stored. This permits the thickness of the steel API Std 650 cylindrical liquid-storage tank needed as well as other specifications of how the tank is built to be determined by the weight of the API 650 tank.Service concept: first time to understand customer needs, first time to solve customer worriesVision: to be the leading steel materials supplier in the worldWorking principles: Keep promises; Spare no efforts; Be practical and innovative; Pursue excellenceTalent concept: build a team with a dream and complete a dream with a team!Family culture: we rely on the principles of equality, trust, appreciation and family love to form a harmonious and warm family!The factors that affect the "small breathing" loss of API Std 650 cylindrical liquid-storage tank are: 1. Generally, the larger the storage tank is, the larger the total open area is, the larger the evaporation area is, and the greater the "small breathing" loss is; conversely, the smaller the storage tank is, the smaller the evaporation area is and the smaller the "small breathing" loss is. 2. It is related to the atmosphere. The lower the atmospheric pressure is, the greater the "small breathing" loss is; otherwise, the loss is reduced.
Latest NewsMore+