API Std 650 carbon steel storage tanks bottom joints
Allowable compressive stresses shall be in accordance with 5.5.4 except that for aluminum alloy plate the allowable compressive stresses shall be reduced by the ratio of the modulus of compressive elasticity to 29,000 for values of (t – c)/R less than 0.0175 and by the ratio of the minimum yield strength for the aluminum alloy in question to 30,000 for values of (t – c)/R equal to or greater than 0.0175 (see 5.5.2 for definitions). In all other equations in this standard API Std 650 carbon steel storage tanks where yield strength or modulus of elasticity is used, such as Equations 27 and 28, similar corrections shall be made for aluminum alloys.
API 650 Application As described by the American Petroleum Institute, the fabrication and installation of our surface welded API Std 650 carbon steel storage tanks steel storage tanks is normally used in industrial applications. In general, our standards for industrial on-site installation of storage tanks are established according to API 650, API 620 and API 12D.
The lip seal of floating roof storage tank, API Std 650 carbon steel storage tanks relies on the sliding contact between elastic lip and tank wall. This kind of seal has strong applicability, but the requirements of manufacturing technology and material selection are high, and the determination of elastic seal also exists. The secondary seal of floating roof storage tank, API Std 650 carbon steel storage tanks is to add a seal on the basis of primary seal. It is proved by experiments that the secondary seal can reduce the liquid consumption by more than 50%, and has a more significant effect in safety.