API Std 650 aboveground petroleum storage tanks national standards plates

API 650 petroleum storage tank stipulates that if the thickness of the lower siding obtained by calculating the anti-overturning moment is greater than the thickness of the API Std 650 aboveground petroleum storage tanks hydrostatic pressure test (both do not include the corrosion margin), the calculated thickness of the above siding required by the hydrostatic pressure is It should also be increased by the same proportion, unless special analysis is performed to determine the seismic overturning moment and corresponding stress at the bottom of each layer of API 650 petroleum storage tank wall.

Generally, the snow load in the API Std 650 aboveground petroleum storage tanks construction area should be considered before the design and construction of the tank. The snow load in the API Std 650 aboveground petroleum storage tanks construction area has an impact on the tank roof design and operation, especially in the area with large snow load, the roof load of large storage tank with large diameter increases. Anti freezing, heat preservation and waterproof measures shall be taken for the additional facilities of storage tanks, such as pumps, breathing valves, flame arresters, detection instruments and thermal insulation layers.

In this project, an elemental area of tank wall used is constructed of ASTM A442 Grade 55 steel plate subjected to a meridional unit force, T1, of 4000 lbf/in.2 tension and a latitudinal unit force, T2, of 5060 lbf/in.2 compression. The meridional radius of curvature, R1, is 75 in., and the length of the normal from the surface to the axis of revolution, R2, is 300 in. The joints in the wall are of double-welded butt-joint construction with a tensile efficiency of 85%. A corrosion allowance of 1/16 in. is required.
The problem in this example is to graphically find the minimum thickness of tank wall required for the given conditions (see 5.10.3.3).
Solution: As determined from Table 5-1, the maximum allowable tensile stress value, Sts, for ASTM A442 Grade 55 steel plate in simple tension is 16,500 lbf/in.2. Since the compressive stress is latitudinal, the governing value of R in this situation is R1, or 75 in.

Our company attaches great importance to technical support and after-sales service, and has established a customer service center to provide unified technical support and service for API Std 650 aboveground petroleum storage tanks various engineering projects. Customer service center has a strong technical force of technical service team, composed of a customer service center manager, several API Std 650 aboveground petroleum storage tanks after-sales service personnel, responsible for unified acceptance and processing of local after-sales service needs.

Our company is located in the Central Plains, Zhengzhou City, convenient transportation. There is the largest Xinzheng airport, welcome customers from all over the world to visit our company. Our factories are all located near the port. The logistics is very convenient, which can save the delivery time.