API Std 650 aboveground petroleum storage tanks designed to operate under external pressure conditions

Steel transportation because of the special material of API Std 650 aboveground petroleum storage tanks steel, is a metal with "iron" as the main basic element, small volume and large weight, and easy to oxidize and rust when contacting with air and rain water, so there are many precautions in the transportation of steel. There are 11 proverbs for steel transportation: "evenly placed, moisture-proof and rust proof". Our company chooses the logistics aspect to be very rigorous, takes the customer's request as the standard, guarantees the steel product quality.The thickness of the API Std 650 aboveground petroleum storage tanks annular bottom plates shall be in accordance with Table Q-4 (for steel or aluminum, as applicable). The thicknesses shown are minimums. The ring of annual plates shall have a circular outside circumference, but it may have a regular polygonal shape inside the tank shell with the number of sides equal to the number of annular plates. These pieces shall be butt-welded in accordance with Q.7.1.1, Item b. The plates of the first shell course shall be attached to the annular bottom plates by a weld as required by API 620 oil tank 5.9.5 except when a full-penetration weld is used or required (see Q.7.1.1). Butt-welds in annular plates shall be not closer than 12 in. from any vertical weld.The company will rely on its good reputation, excellent hot-rolled plates, steel pipes, steel structure products, and intimate API Std 650 aboveground petroleum storage tanks after-sales service to customers. I would like to express my heartfelt thanks to the old and new friends and customers who have always given care, support and help to the company! The company sincerely hopes to establish a long-term cooperative relationship with them, mutual benefit and common development. Welcome to come and visit our API Std 650 aboveground petroleum storage tanks steel mill.API 650 petroleum storage tank pipeline stress and product pressure, tank pressure, uniform or non-uniform temperature difference between the tank wall and the tank bottom, which cause the radial displacement and longitudinal rotation of the API Std 650 aboveground petroleum storage tanks tank wall at the opening to affect the oil tank wall The impact is obvious. Therefore, the design must ensure that the load applied by the external pipeline on the opening of the tank wall is within the safety limit. If the stress of the API Std 650 aboveground petroleum storage tanks connecting piping is not handled properly, the wall of the API 650 petroleum storage tank may deform or even rupture, causing a major accident.The seal of floating roof API Std 650 aboveground petroleum storage tanks is a device used to reduce the evaporation loss of the storage liquid in the annular space between the tank wall and the outer ring plate of the floating roof. The common sealing forms include mechanical seal, elastic filling seal, lip seal and secondary seal. No matter what kind of seal, the seal must be combined with the floating roof effectively to reduce the evaporation loss of the liquid in the floating roof.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!