API Std 650 aboveground petroleum storage tanks depth of fusion

The calculated thickness of the above-mentioned wall panels required by the hydrostatic pressure is also It API Std 650 aboveground petroleum storage tanks should be increased by the same ratio, unless special analysis is performed to determine the seismic overturning moment and the corresponding stress at the bottom of the wall of each layer of API 650 tank.

In this project, an elemental area of tank wall used is constructed of ASTM A442 Grade 55 steel plate subjected to a meridional unit force, T1, of 4000 lbf/in.2 tension and a latitudinal unit force, T2, of 5060 lbf/in.2 compression. The meridional radius of curvature, R1, is 75 in., and the length of the normal from the surface to the axis of revolution, R2, is 300 in. The joints in the wall are of double-welded butt-joint construction with a tensile efficiency of 85%. A corrosion allowance of 1/16 in. is required.
The problem in this example is to graphically find the minimum thickness of tank wall required for the given conditions (see 5.10.3.3).
Solution: As determined from Table 5-1, the maximum allowable tensile stress value, Sts, for ASTM A442 Grade 55 steel plate in simple tension is 16,500 lbf/in.2. Since the compressive stress is latitudinal, the governing value of R in this situation is R1, or 75 in.

The finned tube heating device for high temperature heat transfer oil for large API Std 650 aboveground petroleum storage tanks has the advantages of convenient inspection and maintenance. The high-efficiency fin heating coil assembly is composed of spirally arranged finned coils. The fins are mainly arranged in the straight pipe section, and the whole assembly is supported by several angle steel supports. The high-efficiency fin heating coil component can enter and exit from the manhole of the API Std 650 aboveground petroleum storage tanks, which is convenient for maintenance and repair.

Team concept: respect, communication, coordination and symbiosisBusiness philosophy: leading by strategy, driving by innovation, creating valueManagement concept: goal oriented, efficient operation, stimulation of vitality and continuous improvementQuality concept: standard guidance, control process, craftsman spirit, leading serviceTalent concept: lifelong learning, give full scope to the talents, the sea refuses no riverInnovation concept: innovation is the first driving force for the company's high-quality developmentCustomer concept: taking customers as the center is the foundation of the company's survival and development

In addition to our own truck fleet, we also have long-term cooperation with certain logistics companies to ensure that we can deliver API Std 650 aboveground petroleum storage tanks goods in time and smoothly. At the same time, because of the long-term cooperation and huge shipping volume, we can get a good transportation price and save transportation cost for the company and customers. Meanwhile, we have Shipping Department to arrange shipping work in advance. So as not to waste time on transportation both in land and on the sea.

We guarantee to provide all technical data required by users within one hour to provide reasonable quotation; to provide API Std 650 aboveground petroleum storage tanks reasonable quotation for products consulted by users within one hour; to provide investigation reception: we guarantee to receive the investigation of users at any time and provide various convenient conditions for users.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!