API standard 650 welded steel oil storage tanks bearing load

Insulation Load
For API 620 tanks designed and constructed with an outer tank containing loose fill insulation in the annular space between the tanks, the insulation weight shall be divided equally to the inner and outer tank wall for seismic lateral loads unless a more rigorous analysis is performed to determine the distribution. The insulation within the annular space shall not be used to calculate resistance to overturning. Insulation on the API standard 650 welded steel oil storage tanks roof or suspended deck shall be applied to the tank supporting the load at the point or center of gravity of attachment and may be used to resist overturning.

API 650 is the standard for welded tanks for oil storage. It specifies the design, manufacturing, welding, inspection and installation requirements of oil tanks. API 650 API standard 650 welded steel oil storage tanks is widely used in storage tanks with internal pressure less than or equal to 2.5 PSI, used to store products such as crude oil, gasoline, chemicals, and produced water. BBN has extensive experience in API standard 650 welded steel oil storage tanks API 650 tanks with diameters between 8'-300', suitable for refineries, terminals, pipeline facilities and other customers.

This customer is a leading Engineering, Procurement and Construction company serving the Hydrocarbon and Chemical industries spanning Oil & Gas, Petrochemical, Refining, Fertilizer and related sectors in India. The A335 Grade P5 Steel Pipe and P9 API standard 650 welded steel oil storage tanks Seamless Steel Pipe we supplied is for EIL refineries project.

}

The safety inspection of atmospheric storage tank, API standard 650 welded steel oil storage tanks is divided into external inspection, internal and external inspection and comprehensive inspection. External inspection shall be conducted at least once a year, internal and external inspection shall be conducted at least once every three years, and comprehensive inspection shall be conducted at least once every six years. The safety inspection of large atmospheric storage tanks, API standard 650 welded steel oil storage tanks requires special attention: the parts where the liquid level often fluctuates, the parts that are susceptible to corrosion, and the parts that are deformed and worn during use should be checked.

The company is deeply supported and loved by customers with its unique business philosophy and business model. The company has always been adhering to the "credibility first, integrity-based, quality first" purpose, and sincerely serve new and old customers. Over the past twenty years, the company has won the trust of customers by relying on good service and good reputation. Our aftersales team’s main responsibility is to deal with quality feedback and complaints from Customer.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!