API standard 650 welded aluminum storage tanks design metal temperature
Surface Inspection of low-pressure storage tank Component PartsBefore assembly, unless already so certified by shop inspectors, all sidewall plates or sections and roof and bottom plates shall be inspected for thickness, freedom from injurious defects, and soundness of any welded joints.Check of Dimensions of API standard 650 welded aluminum storage tanks Component PartsAll formed plates and curved sections shall be checked for conformance with the planned dimensions and cross section. For unusual repairs the inspector should keep a record of measurements taken at sufficient intervals to constitute a satisfactory record.Check of Chemical and Physical Property DataThe inspector shall check the material being assembled by the lists of the plates from the mill, their heat numbers, chemical analyses, and mechanical properties as given on mill reports and shall see that copies are available to be attached to the Manufacturer’s report.
The temperature requirements of the API 650 oil storage tank area are closely related to the evaporation loss, energy loss, API standard 650 welded aluminum storage tanks storage and storage platform tank materials and the selection of detection instruments, or the temperature of the API 650 oil storage tank area. The cost of storage has a direct impact.
Our client purchase more than 900 tons pipe API standard 650 welded aluminum storage tanks from India. And we do the inspection for each one pipe before shipment.During the inspection, the inspector saw that the surface of the square pipe kept the original color of the stainless steel, no fracture, no depression and other quality defects was found.
}Compared with the external floating roof API standard 650 welded aluminum storage tanks, the internal floating roof API standard 650 welded aluminum storage tanks has the advantages of protecting the floating roof from wind and rain and ensuring the quality of liquid storage under the floating roof. At the same time, because the inner floating plate is in the tank, there is no rain and snow load, so the central drainage pipe and escalator and other accessories on the floating plate can be omitted. In addition, under the same sealing conditions, the internal floating roof tank can further reduce the evaporation loss compared with the External floating roof tank.
Due to other non-steel quality reasons caused by the customer dissatisfaction, to timely explain to the customer, and help them solve the problem, for the customer really because of their own reasons, to give patient reply.The process of objection handling is the process of our technical service.