API standard 650 horizontal tank anchorage ratio

Soil Structure Interaction: Soil structure interaction per API 650, Section E.6.1.6 may be used for OLE design providing the damping ratio does not exceed 10 %.
Allowable Stresses
Design allowable stresses shall be per API 620 large welded steel storage tank, Section Q.3.3, including the 33 % increase permitted for earthquake loads.
Self-anchored Inner Tank
The anchorage ratio for a self-anchored inner tank, J, shall not exceed 1.0 for the OLE design combination to limit uplift and stresses in the annular plate and corner weld.
Foundation Stability
The overturning ratio defined in API 650, Section E.6.2.3, Equation (E.6.2.3-1) shall be equal to or greater than 3.0 for the defined OLE event.

API standard 650, Welded Tanks for Oil Storage, Thirteenth Edition, has been published to ensure the safety, sustainability, and environmental performance of API standard 650 horizontal tank oil storage tanks. The updated standard will help continue operational excellence and trust between operators and manufacturers.

API standard 650 horizontal tank, Vertical oil storage tank is an important equipment for many enterprises to carry out production, which provides important support and help for the storage of many reagents. Vertical storage tank is generally used as atmospheric pressure vessel. Advantages: the filling rate of cylindrical structure is second to that of spherical tank, and the largest volume of the storage tank can be made into tens of thousands of cubic meters. The structure is simple and the construction requirements are relatively low.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!