API standard 650 ground supported liquid storage tanks low-type nozzles

API standard 650 ground supported liquid storage tanks Visual InspectionUpon completion of all the foregoing tests, the pressure in the tank shall be released and a thorough visual inspection shall be made of both the inside and outside of the tank, giving particular attention to all internal ties, braces, trusses, and their attachments to the walls of the tank. Anchors shall be checked for snug tightness and adjusted if required. Anchor threads shall be fouled by peening or tack welding to prevent loosening. In lieu of thread fouling, double nuts may be used.Rate of Water Filling and Water TemperatureThe rate at which water is introduced into a tank for a hydrostatic test shall not exceed 3 ft of depth per hour. The foundation, venting equipment, or other conditions may limit the water filling to a lower rate. Pressure shall not be applied above the surface of the water before the tank and its contents are at about the same temperature.

The floating roof is the top cover floating on the liquid level, so the sealing performance of API standard 650 ground supported liquid storage tanks API 650 oil storage tank is very important. The floating plate mainly adopts elastic packing, and at the same time, it is compressed with the wall of API 650 oil storage tank with pressure strip around, and fixed with the floating plate with bolts. After the API standard 650 ground supported liquid storage tanks floating plate is lowered to a certain position of about 1.8m, a prop will support the floating plate to keep it in position.

In 2013, one of our clients in Korea purchased 890 tons Q345B square tube from us for one building construction project. Our clients required no burr in the side of the tube, we finally produce the goods with great condition and +/-0.25mm tolerance for wall thickness, which is a very great tolerance with customers’ required size. Our square tube full available range is 2-16mm for wall thickness, and 40-500mm for width. In addition, our Q/C department will seriously control all of the process of every order.

}

The cone slope of the completed API standard 650 ground supported liquid storage tanks foundation is 15/1000 for the general foundation and less than 35/1000 for the soft foundation. After the foundation settlement of the storage tank is basically stable, the surface slope must be greater than eight thousandths. The edge of the tank bottom should be more than 0.3 meters higher than the surrounding ground. Above the ground, the tank bottom leakage detection tube should be drawn from the foundation sand cushion and cross the foundation ring wall or the slope protection surface. The circumferential distance should be less than 20 meters, and each API standard 650 ground supported liquid storage tanks should have at least 4 detection tubes.

Both parties shall confirm the API standard 650 ground supported liquid storage tanks material object and the quality of the products, confirm the reasons for the defects and the quality of the products, and sign the quality inspection agreement. Major quality objections shall be reported to relevant leaders in a timely manner, and shall be discussed and solved with the API standard 650 ground supported liquid storage tanks steel plant.