The company focuses on teamwork and builds a team with a dream. For society: we focus on quality first, integrity-based, service-oriented create value for customers and wealth for the society. For employees, the company promote healthy living, happy work, unity, innovation. For working, we seek the efficient operation, the pursuit of excellence. Welcome to come, visit our office building and join us.
Define the welding sequence of API standard 650 ground-supported liquid storage tanks bottom plate: the welding sequence of metal vertical storage tank shall be carried out according to the procedure required by the welding scheme. Spot welding shall be consistent with the formal welding requirements, and no spot welding shall be carried out for the weld not welded. Back bar should be added to prevent deformation when welding the full length seam of middle plate, butt joint of edge plate and turtle shell joint.
Allowable compressive stresses shall be in accordance with 5.5.4 except that for aluminum alloy plate the allowable compressive stresses shall be reduced by the ratio of the modulus of compressive elasticity to 29,000 for values of (t – c)/R less than 0.0175 and by the ratio of the minimum yield strength for the aluminum alloy in question to 30,000 for values of (t – c)/R equal to or greater than 0.0175 (see 5.5.2 for definitions). In all other equations in this standard API standard 650 ground-supported liquid storage tanks where yield strength or modulus of elasticity is used, such as Equations 27 and 28, similar corrections shall be made for aluminum alloys.