API standard 650 flat-bottom tanks Visual InspectionUpon completion of all the foregoing tests, the pressure in the tank shall be released and a thorough visual inspection shall be made of both the inside and outside of the tank, giving particular attention to all internal ties, braces, trusses, and their attachments to the walls of the tank. Anchors shall be checked for snug tightness and adjusted if required. Anchor threads shall be fouled by peening or tack welding to prevent loosening. In lieu of thread fouling, double nuts may be used.Rate of Water Filling and Water TemperatureThe rate at which water is introduced into a tank for a hydrostatic test shall not exceed 3 ft of depth per hour. The foundation, venting equipment, or other conditions may limit the water filling to a lower rate. Pressure shall not be applied above the surface of the water before the tank and its contents are at about the same temperature.
API 650 vertical tanks meet American Petroleum Industries (API) standards in design, material, fabrication, and testing of aboveground welded steel API standard 650 flat-bottom tanksstorage tanks for use in industrial applications.
3500 tons SA387GR5CL1 steel plate to make pressure vessel equipment in Pakistan. The main business of our this client from Pakistan is manufacturing Columns&Towers, Heat Exchanger,Waste Heat Recovery Boiler, Pressure Vessel&Reactors,Tanks, Metering Skid. And we supply API standard 650 flat-bottom tanks the Mill Certificate, Shipping picture, the marking of steel plate and we help client to do SGS inspection.
}The most popular standards for API standard 650 flat-bottom tanks are API Std 650, JIS B8501, BS2654, GB50341, etc. The formulas used in each standard are derived from the hoop stress calculation formula of membrane theory. Combined with the stress characteristics of API standard 650 flat-bottom tanks, plus the allowable stress, weld coefficient and additional wall thickness, the wall thickness calculation formula is complete. The allowable stress and weld coefficient are determined according to the material performance characteristics and construction technology level of each country. According to different API standard 650 flat-bottom tanks standards, the calculation results of tank wall thickness are sometimes quite different.
The company's after-sales service tenet is "customer first, timely guarantee, enthusiastic service and effective work". In order to establish a set of perfect after-sales service system and strict management system, so that the after-sales service can be effectively guaranteed. The company has set up after-sales service department to ensure timely, unique and effective response to every user's request, coordinate internal resources internally, and put an end to all evasion and delay.