API standard 650 closed top welded storage tanks external floating roofs
Before pressure test, the main drain hose system of API 650 petroleum storage tank floating roof should be thoroughly flushed. Provide blind flanges, gaskets and bolts required for the API standard 650 closed top welded storage tanks test (other types of covers are also required if necessary). Covers for maintenance shall be provided in accordance with the interfaces specified by API 650 petroleum storage tanks, and these seals shall remain in place after the test; and for those interfaces that are not provided for maintenance covers, the covers can be removed after the API standard 650 closed top welded storage tanks test.
The main advantages of the external floating roof API standard 650 closed top welded storage tanks are large storage capacity, suitable for storing more than 10000 cubic meters of crude oil. Compared with the internal floating roof API standard 650 closed top welded storage tanks, the production of external floating roof API standard 650 closed top welded storage tanks is simple and the steel consumption is less. However, the central drainage system of external floating roof API standard 650 closed top welded storage tanks should be installed on the outer floating roof to ensure that the accumulated water can be discharged smoothly in rainy and snowy days, and avoid sinking accident.
Foundations and subgrade shall safely carry the weight of the tank API standard 650 closed top welded storage tanks and its contents when the tank is filled with water to the highest level required for a hydrostatic test or other water-loading operations, even though the tank itself may be designed for some lesser density of liquid. However, in cases where the character of the soil justifies it and a competent soil expert advises it, allowance may be made for the relatively short duration and intermittent nature of the water loadings if suitable account is taken of all such loadings that may be expected to occur during the life of the tank, including not only those loadings that are incidental to periodic repetitions of the hydrostatic test in accordance with 7.18 but also water-filling operations for gas-freeing purposes.
Since the foundation of the company, the Spring Festival Gala is an annual activity held at the end of the year. Now it is a part of the BBN company culture to enrich the employee's life. The annual Spring Festival Gala in 2019 was held on January 20, 2020. There are opening ceremony, leader's speech, BBN steel performance, awards for outstanding employees, lucky draw, party game, curtain call, company group photo, annual Gala dinner and other links.
Japan is a typical shipping first, and its raw materials are imported from Oceania, central and South America and other Asian countries. Most of the API standard 650 closed top welded storage tanks steel produced is exported to China and other Asian countries, and a small amount is exported to America. Shipping is the main way of its API standard 650 closed top welded storage tanks steel international transportation. According to the data, steel goods account for about 20% of the total sea freight in Japan. The domestic transportation of Japanese steel is mainly truck.