API standard 650 carbon steel storage tanks rod, bar, and structural shapes

Our company is a specialized technical support and after-sales service organization - customer service center. At the same time, we have provided excellent technical API standard 650 carbon steel storage tanks personnel and strong technical support for our company, and cultivated an excellent after-sales team for our company. Our company will appoint a full-time service manager to be responsible for the unified coordination of technical support and API standard 650 carbon steel storage tanks after-sales service of the project.The thickness of the API standard 650 carbon steel storage tanks wall plate, t, required by 5.10.3 for the latitudinal unit forces, T2, acting at this level is 0.57 in. The nozzle neck is seamless steel pipe and conforms to ASTM A53, Grade A; the materials in the tank wall and reinforcing pad conform to ASTM A442 Grade 55. The main joints in the tank walls are fully radiographed, double-welded butt joints. The adequacy of the reinforcement and attachment welds shown in Figure F-7 shall be determined.
To determine the length of the nozzle neck within the limits of reinforcement, the smaller of the following calculated values shall be used:(2.5)(0.625) = 1.56 in.
(2.5)(0.375) + 0.75 = 1.69 in.The welded steel API 650 storage tank API standard 650 carbon steel storage tanks is designed, manufactured and installed on the surface according to the API standard system classification. API 650, API620 and API 12D belong to the API standards for professional construction.Customer concept: customer first. Guided by market changes and guided by customer needs, we design the optimal product solutions and provide the best after-sales service. Partners: to reach a balance of interests with all stakeholders, to build a harmonious coexistence and win-win cooperation.Usually, the wind load in the API standard 650 carbon steel storage tanks construction area should be considered before the tank design and construction. The wind load in the API standard 650 carbon steel storage tanks construction area has an impact on the stability and economy of the API standard 650 carbon steel storage tanks. In the area with large wind load, it is safe to design the tank as "squat". When calculating the wind force, the influence of the thickness of the insulation layer of the API standard 650 carbon steel storage tanks, the shape of the ladder, the platform, the pipeline and the top cover must be considered.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!