API standard 650 aboveground welded storage tanks selection guidelines
The technology center has always been focusing on application research, improving market realization and scientific and technological contribution rate; taking user demand as the goal, highlighting the personalized development of products; taking the joint development of industry, University and research, and technology integration as the means, improving the starting point and level of innovation, and realizing the breakthrough of core technology; taking advanced research as the guide, pursuing the leap of technological development; taking system and mechanism innovation as the driving force, Promote and realize the working concept of technological innovation.Preheating should be performed by heating and maintaining this heat in appreciable lengths of the joint to be welded, preferably using a strip burner with a mild flame rather than a harsh flame such as that from a cutting torch. Electrical strip heaters are available and have been found to be satisfactory. The preheat of 300°F should be checked with a temperature-sensitive crayon, or similarly accurate means, so that the steel 4 in. (or four times the API standard 650 aboveground welded storage tanks plate thickness, whichever is greater) on each side of the joint will be maintained at the minimum preheat temperature. Ring burners or heaters are recommended for nozzle and manway welds. At no time during the welding should the base metal fall below a temperature of 300°F.This standard applies only to API 650 tank API standard 650 aboveground welded storage tanks whose entire bottom is uniformly supported and to API 650 tank in non-refrigerated service that have a maximum design temperature of 93°C (200 °F) or less.Firmly establish the "people-oriented, safe development" concept, strictly follow the safety production policy of "safety first, prevention first, comprehensive management", strengthen and improve the management and supervision of safety production in an all-round way, and strive to improve the controllability of safety management And effectiveness, cultivate safety culture, improve long-term safety production mechanism, and build a harmonious BEBON.All oil tanks have service life. Due to the pressure of the oil stored on the tank and the corrosion of the oil and external environment on the tank, the oil storage tank will gradually become thin or crack after a long time. Due to the different materials and environment of API standard 650 aboveground welded storage tanks, the consumption of API standard 650 aboveground welded storage tanks is different, so it should be taken into account when evaluating the remaining service life of API standard 650 aboveground welded storage tanks.
Latest NewsMore+