API 650 self-anchored tank nomenclature
Stamping of API 620 storage tank PlatesBefore plates required to be stamped by the steel mill are used, the inspector shall see that they bear the stamp. In laying out and cutting the API 650 self-anchored tank plates, at least one set of the original material identification markings should, if possible, be left where it will be plainly visible when the tank is completed. Should the identifying marks be obliterateSpot radiographic or ultrasonic examination shall be not less than 6 in. extending along the weld. Spot radiography shall comply with the standards given in 7.15.1.3. Where spot radiographic or ultrasonic examination is applied at joint intersections, the surface shall be prepared and examined for a distance of 3 in. on each side of the intersection, making the minimum length of examination 6 in. on the horizontal weld and 3 in. on the vertical weld.
This API 650 tank standard does not present orstablish a fixed series of allowable tank sizes: instead, it s intended to permit the purchaser to select whatever size API 650 self-anchored tank tank may best meet his needs.
The elastic filling and sealing of floating roof API 650 self-anchored tank is to fill the elastic and changeable objects in the sealed envelope, and the sealing purpose depends on the compression deformation of the filler. This kind of sealing effect is good, the requirement of the geometry of tank wall is not too high, and the adaptability is strong. However, the elastic filling and sealing has poor wear resistance and is easy to deform and damage in long-term use.