API 650 mechanically-anchored tanks fabrication

Surface Inspection of low-pressure storage tank Component PartsBefore assembly, unless already so certified by shop inspectors, all sidewall plates or sections and roof and bottom plates shall be inspected for thickness, freedom from injurious defects, and soundness of any welded joints.Check of Dimensions of API 650 mechanically-anchored tanks Component PartsAll formed plates and curved sections shall be checked for conformance with the planned dimensions and cross section. For unusual repairs the inspector should keep a record of measurements taken at sufficient intervals to constitute a satisfactory record.Check of Chemical and Physical Property DataThe inspector shall check the material being assembled by the lists of the plates from the mill, their heat numbers, chemical analyses, and mechanical properties as given on mill reports and shall see that copies are available to be attached to the Manufacturer’s report.Determination of API 650 oil tank container: The total volume should be determined according to factors such as transportation mode and API 650 mechanically-anchored tanks fuel supply cycle. For train and ship transportation, the maximum consumption is not less than 20-30 days; the maximum consumption for automobile transportation is not less than 5-10 days.our company supplied 2300 ton API 5L GrB ERW pipe to Petroleum company in 2016. It takes 35 days for our company to finish all the production according to API 5L standard. The products are used to drilling , gas transmission works. And we supply the API5L PSL1 GR B original Mill Test Certificate, API5L PSL1 GR B pipes picture, the dimension test, the API 650 mechanically-anchored tanks material, heat number, supplier name and size will be shown on the surface of steel pipe,API 650 mechanically-anchored tanks. Manhole: The manhole is used for the operator to enter and exit the oil tank for inspection, cleaning and repair. For the convenience of personnel access, the installation position of the manhole is generally on the center line of the oil tank bottom, and the vertical oil tank is installed at the lowest layer of the tank wall. API 650 mechanically-anchored tanks Light-transmitting hole: Light-transmitting hole is also called day-lighting hole. It is used for lighting and ventilation when inspecting, repairing and scrubbing the oil tank. It is generally installed on the top of the oil tank above the inlet and outlet pipes.Our company has established and constantly improved the customer service system and emergency response system. Through the customer service management system, we track the service of the after-sales service team and provide efficient and standard services in time. At the same time, the company formulates a regular return visit system, compares the historical cases of customer problems, proposes a pre solution, and ensures that the service is in place in a short time.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!