API 650 ground-supported liquid storage tanks heat-affected zone
API 650 storage tank stipulates that if the thickness of the lower wall panel obtained by calculating the anti-overturning moment is greater than the thickness of the API 650 ground-supported liquid storage tanks hydrostatic pressure test (both do not include the corrosion allowance).
Ultrasonic Examination of Butt-welds in PlatesButt-welds in all tank wall courses subjected to a maximum actual operating membrane tensile stress, perpendicular to the welded joint, greater than 0.1 times the specified minimum tensile strength of the API 650 ground-supported liquid storage tanks plate material shall be completely examined.Butt-welds in API 620 oil tank wall courses subjected to maximum actual operating membrane tensile stress, perpendicular to the welded joint, less than or equal to 0.1 times the specified minimum tensile strength of plate material shall be spot examined in accordance with Figure Q-2.
API 650 ground-supported liquid storage tanks Manhole: The manhole is used for the operator to enter and exit the oil tank for inspection, cleaning and repair. For the convenience of personnel access, the installation position of the manhole is generally on the center line of the oil tank bottom, and the vertical oil tank is installed at the lowest layer of the tank wall. API 650 ground-supported liquid storage tanks Light-transmitting hole: Light-transmitting hole is also called day-lighting hole. It is used for lighting and ventilation when inspecting, repairing and scrubbing the oil tank. It is generally installed on the top of the oil tank above the inlet and outlet pipes.
Enterprise Motto:Integrity, harmony, dedication, innovation and developmentAbility is the cornerstone of success; action is the ladder of successGrow with the enterprise; progress with the enterpriseGive a platform to those who actually do things and a stage to those who successfully do thingsDare to be the first, to pursue excellence.
The trend of international shipping development of large-scale ships and strategic joint ventures puts forward higher requirements for modern ports. Modern ports no longer use the general cargo throughput as a measure sign, and container throughput will become the main sign to measure the role and status of modern ports. The average container capacity in 2000 is 3200teu, and it is expected to be 5500teu in 2020.
If customers have any difficult problems during use of the steel materials, they can contact the company's after-sales service department to feedback the existing problems. The after-sales department will reply as soon as possible to ensure that each customer has a good after-sales experience. Under special circumstances, the after-sales service department will start the problem-solving process, and the engineers in charge of the area will quickly follow up to solve the problem.