API 650 flat-bottom oil storage tanks pontoon design
The refrigerated tank primary components shall also include those parts of a single-wall or an inner tank that are not in contact with the refrigerated liquid but are subject to the refrigerated temperature. Such API 650 flat-bottom oil storage tanks components include roof plates, roof manways and nozzles with their reinforcements, roof-supporting structural members, and shell stiffeners when the combined tensile and primary bending stresses in these components under design conditions are greater than 6000 lbf/in.2.
The thickness of the overburden on the top of the API 650 oil tank should not be less than 0.5m. The surrounding backfill with clean sand or fine soil should be no less than 0.3m thick; the API 650 oil tank API 650 flat-bottom oil storage tanks operation platform ladder selection unit is considered in a unified manner. The buried operation well is designed for buried horizontal oil tanks, and the two are compatible.
The bottom plate of the vertical API 650 flat-bottom oil storage tanks directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API 650 flat-bottom oil storage tanks, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.