A516 grade 70 plates API standard 650 self-anchored flat-bottom steel tanks

Design of a Double-wall Tank
The outer bottom, shell, and roof of a double-wall tank shall enclose an insulating space around the bottom, shell, and roof or insulation deck of the inner tank that contains the stored liquid. The annular space shall be maintained at a low positive pressure, which necessitates that the enclosure be vapor-tight. The Purchaser shall specify the design metal temperature and pressure of the inner tank and may specify the design temperature and pressure of the outer tank API standard 650 self-anchored flat-bottom steel tanks. The Purchaser shall state the specific gravity of the content to be stored, roof live loads, wind load, earthquake load where applicable, and corrosion allowance, if any.

The seismic effects on the tank wall of API 650 oil storage tank include the inertia moment generated by the weight of the API standard 650 self-anchored flat-bottom steel tanks tank and the hydrodynamic pressure of the reservoir, which can be divided into short period pulse pressure and long period fluid slopping convective pressure.

LSAW Pipe to Peru. In the beginning of 2014, Peru government released an international tender for one of the hydroelectric power plant. Finally they chose us as the contractor, we purchased the steel plate and then fabricate the API standard 650 self-anchored flat-bottom steel tanks steel plate into steel pipe, and then make the corrosion protect on the surface, we also supply the fitting with our steel plate, the total value of this order is about 2 million USD.

}

High temperature heat transfer oil fin tube heating device for large API standard 650 self-anchored flat-bottom steel tanks has the advantage of reducing the leakage of heating coils. The heating medium of the large storage tank heating device is high-temperature heat-conducting oil. The boiling point of the heat-conducting oil is high, usually higher than 200°C. At high temperatures, the pressure on the heat-conducting oil circulation pipeline is very small, which greatly reduces the occurrence of heating coil leakage accidents. At the same time, the temperature difference between the inside and outside of the tube is guaranteed.

The after-sales service department will pay return visit to each customer by call or email, report problems found during the return visit in time, and discuss with the production and quality inspection center to propose effective solutions and follow up in a timely manner, so as to ensure the benefits each customer are fully guaranteed, and to provide customers with more value-added services.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]