A516 grade 450 plates API Std 650 open top welded storage tanks
Pressure Setting of Safety DevicesExcept as provided in API 620 tank 9.5 for certain liquid relief valves, the pressure setting of a pressure-relieving device shall in no case exceed the maximum pressure that can exist at the level where the device is located when the pressure at the top of the tank equals the nominal pressure rating for the tank (see API 620 tank 5.3.1) and the liquid contained in the tank API Std 650 open top welded storage tanks is at the maximum design level.Vacuum-relieving devices shall be set to open at such a pressure or partial vacuum that the partial vacuum in the tank cannot exceed that for which the tank is designed when the inflow of air (or other gas or vapor) through the device is at its maximum specified rate.
API 650 is the standard for welded tanks for oil storage. It specifies the design, manufacturing, welding, inspection and installation requirements of oil tanks. API 650 API Std 650 open top welded storage tanks is widely used in storage tanks with internal pressure less than or equal to 2.5 PSI, used to store products such as crude oil, gasoline, chemicals, and produced water. BBN has extensive experience in API Std 650 open top welded storage tanks API 650 tanks with diameters between 8'-300', suitable for refineries, terminals, pipeline facilities and other customers.
We supply 3500 tons SA387GR5CL1 steel plates to Pakistan. The main businesses of the Pakistan customer are manufacturing columns & towers, heat exchanger, waste heat recovery boiler, pressure vessel & reactors, tanks, etc. We arranged SGS test for the SA387GR5CL1 steel plates. The test contents include chemical composition analysis, tensile test, impact test, etc. The test results are satisfied. The Pakistan customer gave good feedback after receiving the SA387GR5CL1 steel plates.
}Anti corrosion of API Std 650 open top welded storage tanks:After using for a certain period of time, it is necessary to check the corrosion protection of the API Std 650 open top welded storage tanks. If necessary, the outer wall of the metal oil tank should be painted with new anti-corrosion paint to ensure that the outer wall of the API Std 650 open top welded storage tanks does not fall off and has good waterproof and rust resistance.API Std 650 open top welded storage tanks cleaning:The long-term use of API Std 650 open top welded storage tanks will produce impurities on the tank wall and deposit on the tank bottom, resulting in tank corrosion to leakage. According to the safety standard of oil tank, the API Std 650 open top welded storage tanks shall be cleaned and derusted regularly to ensure the quality of oil stored and the safety of oil tank equipment.
The company adopts one-to-one fast service and has formed a professional after-sales service team to deal with various problems reflected by customers as soon as possible. At the same time, a traceable product traceability system has been established. It has always been placed at an important core position to resolve customer worries. Our steel API Std 650 open top welded storage tanks products are always committed to “quality issues, life-long replacement”, which is the embodiment of our comprehensive service.