A516 Gr 65 plates API 650 mechanically-anchored flat-bottom tanks

API 620 Tank Standard Post-heat Treatment (Stress Relief)
The post-heat treatment now performed on pressure vessels is of established value, although the mechanism by which the improvement is realized may be open to debate. Post-heat treatment of API 650 mechanically-anchored flat-bottom tanks tank sections when the plate thickness exceeds 11/4 in. is required as stated in 5.25. In special cases, the possibilities of post-heat treatment after erection should be explored. Post-heating an insulated tank may be possible if an ample source of heat is readily available and if the rigidity of the tank is adequate.
The thermal stress-relief treatment performed on pressure vessels is recognized as a means for reducing the probability of brittle failures.

storage tanks API 650 mechanically-anchored flat-bottom tanks built to these standards are spread across U.S. refineries, terminals, pipelines, and production facilities. The API 650 petroleum storage tank detailed standard specifies the design, processing, welding, inspection and installation procedures of the storage tank.

In 2015 , We get the tender from Myanmar Government, the total quantity is 1200 ton ABS-AH36 steel plate, we supply the steel plate with painting ( which standard is according to ISO SA2.5) with gray Color 20 Micron. After Get Customer Contract, Steel Plate Are Produced within 25 days .Then, Goods transported to Tianjin Port And Shipping On Time To Statisfy With Project Expected After Finished Producing. The Steel Quality API 650 mechanically-anchored flat-bottom tanks we offered receive good Praise from our Customers .

}

The manufacturing requirements of bottom plate of vertical metal tank, API 650 mechanically-anchored flat-bottom tanks are as follows: 1. In order to compensate welding shrinkage, the layout diameter of tank bottom is 5-2mm than the design diameter; 2. The butt joint of edge plate of tank bottom shall be machined automatically or semi-automatically; 3. The distance between any two adjacent welding joints on the tank bottom plate and the distance between the butt joint of edge plate and the longitudinal weld of bottom ring wall plate shall not be greater than 200 mm.

Both parties shall confirm the API 650 mechanically-anchored flat-bottom tanks material object and the quality of the products, confirm the reasons for the defects and the quality of the products, and sign the quality inspection agreement. Major quality objections shall be reported to relevant leaders in a timely manner, and shall be discussed and solved with the API 650 mechanically-anchored flat-bottom tanks steel plant.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!