A333 grade 1 pipe API standard 650 anchored tanks
After more than 20 years of ups and downs in the steel industry, BBN company's customers have covered South America, North America, Europe, Africa, Southeast Asia and the Middle East and other countries and regions. We treat every customer who inquires with us sincerely, whether you cooperate with us or not, we will provide you with the best quality steel solutions. Our company team also support the online customer service.Preheating should be performed by heating and maintaining this heat in appreciable lengths of the joint to be welded, preferably using a strip burner with a mild flame rather than a harsh flame such as that from a cutting torch. Electrical strip heaters are available and have been found to be satisfactory. The preheat of 300°F should be checked with a temperature-sensitive crayon, or similarly accurate means, so that the steel 4 in. (or four times the API standard 650 anchored tanks plate thickness, whichever is greater) on each side of the joint will be maintained at the minimum preheat temperature. Ring burners or heaters are recommended for nozzle and manway welds. At no time during the welding should the base metal fall below a temperature of 300°F.API 650 storage tank stipulates that if the thickness of the lower wall panel obtained by calculating the anti-overturning moment is greater than the thickness of the API standard 650 anchored tanks hydrostatic pressure test (both do not include the corrosion allowance).In order to better develop the international steel market and make the steel products trade more prosperous at home and abroad, the company has a number of professional talents who love their posts and are proficient in their business. The company has always been adhering to the "service first, reputation first, customer first, make friends" business purpose, is willing to work together with domestic and foreign customers!The structure of the API standard 650 anchored tanks foundation mainly includes the insulating anticorrosion layer on the top surface of the foundation, the tank wall support, the edge retaining structure, the sand cushion, the oil and water barrier, the detection signal tube and other structures. The construction materials and requirements of each basic structure of the storage tank are different. After the structure of the API standard 650 anchored tanks foundation is built in accordance with the construction requirements, the settlement of the storage tank foundation needs to be observed, and the uneven settlement value of the storage tank foundation should be within the allowable safety range.
Latest NewsMore+