60ft diameter API Std 650 duplex stainless steel tanks
,API Std 650 duplex stainless steel tanks. Visual InspectionUpon completion of all the foregoing tests, the pressure in the tank shall be released and a thorough visual inspection shall be made of both the inside and outside of the tank, giving particular attention to all internal ties, braces, trusses, and their attachments to the walls of the tank. Anchors shall be checked for snug tightness and adjusted if required. Anchor threads shall be fouled by peening or tack welding to prevent loosening. In lieu of thread fouling, double nuts may be used.Rate of Water Filling and Water TemperatureThe rate at which water is introduced into a tank for a hydrostatic test shall not exceed 3 ft of depth per hour. The foundation, venting equipment, or other conditions may limit the water filling to a lower rate. Pressure shall not be applied above the surface of the water before the tank and its contents are at about the same temperature.This standard only applies to API 650 storage tanks API Std 650 duplex stainless steel tanks with uniform bottom support and non-refrigerated service storage tanks with a maximum design temperature of not more than 93 degrees Celsius (200 degrees Fahrenheit).In 2014, we offered 175 ton Cold rolled stainless steel plate to Thailand. The API Std 650 duplex stainless steel tanks products are from TISCO. Here is the MTC that we offered to customer. We have our own quality team. Our quality team will inspect every order before shipment for customer. Normally, we will test the chemical composition, thickness, width, and length. Here are some pictures for last inspection.High temperature heat transfer oil fin tube heating device for large API Std 650 duplex stainless steel tanks has the advantage of high heat transfer efficiency. The high-temperature heat-conducting oil finned tube heating device adopts high-efficiency outer finned tubes. The outer finned tube coils are immersed in a water bath. Compared with ordinary light tubes, the contact area between the evaporation coils and the medium is increased. The total heat transfer coefficient of the coil is determined by the heat transfer coefficient outside the tube. This increases the heat flux per unit tube length and improves the overall heat transfer efficiency.Over the years, the company has strived for perfection, being well-received. By virtue of stable product performance, high-quality engineering effects and perfect service system, we have won the trust of many customers, and our engineering cases and after-sales service systems are spread all over the world. We regularly conduct quality tracking and return visits by phone and email, listen to customers' opinions, and continuously improve service quality.
Latest NewsMore+