50ft diameter API standard 650 ground supported flat-bottom tanks
The interior of API 650 storage tanks to be internally lined or coated must have all edges rounded to a minimum of 3 mm radius. Internal welds must be completely seal welded, ground smooth, and free from API standard 650 ground supported flat-bottom tanks surface porosity, pockets, and high spots. Remove weld spatter. Vendor as specified on API 650 storage tanks drawing must perform additional surface preparation.
The bottom plate of the vertical API standard 650 ground supported flat-bottom tanks directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API standard 650 ground supported flat-bottom tanks, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.
Surface Inspection of low-pressure storage tank Component PartsBefore assembly, unless already so certified by shop inspectors, all sidewall plates or sections and roof and bottom plates shall be inspected for thickness, freedom from injurious defects, and soundness of any welded joints.Check of Dimensions of API standard 650 ground supported flat-bottom tanks Component PartsAll formed plates and curved sections shall be checked for conformance with the planned dimensions and cross section. For unusual repairs the inspector should keep a record of measurements taken at sufficient intervals to constitute a satisfactory record.Check of Chemical and Physical Property DataThe inspector shall check the material being assembled by the lists of the plates from the mill, their heat numbers, chemical analyses, and mechanical properties as given on mill reports and shall see that copies are available to be attached to the Manufacturer’s report.
Our company attaches great importance to technical support and after-sales service, and has established a customer service center to provide unified technical support and service for API standard 650 ground supported flat-bottom tanks various engineering projects. Customer service center has a strong technical force of technical service team, composed of a customer service center manager, several API standard 650 ground supported flat-bottom tanks after-sales service personnel, responsible for unified acceptance and processing of local after-sales service needs.
Facing the new situation and facing new goals, the company revolves around the sixteen-character development policy of “prioritizing production preservation, society-oriented, market operation, and brand creation and efficiency”. Layout the country in accordance with the modern logistics model, and accelerate the establishment of a modern integrated steel enterprise integrating steel storage, transportation, processing, and distribution.