5052 aluminum shapes API standard 650 ground supported liquid storage tanks

API standard 650 ground supported liquid storage tanks Liquid Relief ValvesA tank, which is likely to operate completely filled with liquid, shall be equipped with one or more liquid relief valves at the top of the roof, unless otherwise protected against overpressure. When such valves are, in effect, supplementary relief devices, they may be set at a pressure not greater than 1.25 times the design pressure. Because the relief valve at the pump, which provides the inflow of liquid to the tank, is set at a pressure greater than 1.25 times the design pressure of any tank that may be built under these rules, provision should be made for preventing overfilling of the tank by a self-closing float valve, by some practicable pilot-valve control, or by any other proven device.

Under the action of the earthquake, API 650 storage tank is mainly damaged by the phenomenon of the lower part of the API standard 650 ground supported liquid storage tanks tank wall. Therefore, the key point of seismic calculation is to prevent the tank wall from buckling under axial pressure.

Good news: The largest steel importer in Nigeria ordered 4068 tons API 5L X52Q PSL2 3LPE seamless pipes and also ordered 8 pcs 42699.6 m³big diameter Crude oil storage doom roof tank in A537CL2 steel grade. In Sep 2019, This Nigeria client visited our company and factory, they were very satisfied with our company's quality control,production capacity and service. We also have reached a agreement for Phase II Project, It is also with another 10,000 tons APl 5L X52Q PSL2 3LPE seamless pipes.

}

Requirements for prefabrication of the top of large vertical API standard 650 ground supported liquid storage tanks: The prefabrication of the tank top shall be prefabricated in blocks according to the drawings. Pay attention to the spacing of the welds after installation when setting out the material. Reinforcing ribs should be formed and inspected with an arc-shaped template. When a single top plate needs to be spliced, butt joints should be used. The forming of a single top plate should be welded between the reinforcing ribs and the top plate on the mould. After forming, check with an arc-shaped sample plate, and the gap should not be greater than 10 mm.

Adhere to the spirit of quality first and user foremost, carry out maintenance and other work according to the requirements of the buyer's contract, and ensure that the engineering project and product after-sales play their application effectiveness. Our company guarantees to carry out self inspection and self supervision according to the quality management policy proposed by our company, and deliver a high-grade, perfect and excellent system engineering to users.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]