12m diameter API Std 650 flat-bottom steel tanks

Structural shapes of 9% and 5% nickel steel may be furnished to the chemical and physical requirements of ASTM A353, A553, or A645. Physical tests shall be in accordance with the requirements of ASTM A6.
API Std 650 flat-bottom steel tanks used Piping, Tubing, and Forgings
Material used for piping, tubing, and forgings shall be compatible in welding strength, and thermal expansion coefficient with the tank shell material. In addition to the specific requirements of this appendix, all piping within the limitations of 1.3.2 shall fulfill the minimum requirements of ASME B31.3.

API 650 is an American standard for welding flat bottom vertical storage tanks. This API Std 650 flat-bottom steel tanks standard specifies requirements for the design, manufacturing, welding, inspection and installation of storage tanks. API 650 is widely used in storage tanks designed to withstand low internal pressures and used to store typical products such as API Std 650 flat-bottom steel tanks crude oil, gasoline, chemicals and water. BBN has extensive experience in API 650 tanks, from +/- 500 cubic meters of tanks produced in the factory to +/- 15000 cubic meters of tanks produced on site.

We supply 5800 tons A53 Gr B ERW pipes to Qatar for Qatar Integrated Railway Project - Green Line. This is the first Metro Line in Qatar, and it is located in Doha. We got the order by tender, launched by the Qatar Railways Company for designing, construction and completion of Green Line Project. Before putting order, a delegation from the API Std 650 flat-bottom steel tanks project side visited us and several other famous steel pipe mills in China for 15 days. Finally, we were chosen and finished the task exceeding their expectations.

}

The bottom plate of the vertical API Std 650 flat-bottom steel tanks directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API Std 650 flat-bottom steel tanks, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.

Our company will accept the product quality objection registration record, pass it to the API Std 650 flat-bottom steel tanks production unit and relevant departments, and timely coordinate the supervision of product API Std 650 flat-bottom steel tanks quality objection. Our company coordinates the relevant department personnel to the customer unit to carry on the investigation, the processing.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!